Analysis report block based filtering for profiling (#566)
* Analysis report block based filtering for profiling
* Profiling mode changes
- `-b` option now additionally accepts metric id(s), similar to `-b` option in analyze mode (e.g. 6, 6.2, 6.23)
- Only counters mentioned in the selected analysis report blocks will be collected
- Add parsing logic to identify hardware counters from analysis report blocks
- Add filtering logic to only write filtered counters in perfmon files
- Log not collected counters in one line
- `--list-metrics` option added in profile mode to list possible metric id(s) similar to analyze mode
- Write arguments provided during profiling in profiling_configuration.yaml file
* Analysis mode changes
- During analysis mode, only show report blocks selected during profiling
- If `-b` option is provided in analysis mode, then follow provided filters
- Do not show empty tables in analysis report
* Miscellaneous changes
- Update CHANGELOG
- Add test cases
- Instruction mix report block filter
- Instruction mix and Memory chart report block filter
- Instruction mix report block filter and CPC hardware block filter
- TA hardware block filter
- --list-metrics in profile mode should work
- Move binary handler fixtures to conftest.py to avoid importing
fixtures
- cmake file in tests directory has been updated to compile sample/vmem.hip for testing
* Public documentation changes
- Use the term "Hardware report block" instead of "Hardware block"
- Add documentation for "--list-metrics" option in profile mode
- Add example of filtering by hardware report block such as instruction
mix and wavefront launch statistics
- Add deprecation warning for hardware component (sq, tcc) based filtering
This commit is contained in:
committed by
GitHub
orang tua
0aefd15b7b
melakukan
55cf0e237e
+15
-2
@@ -191,7 +191,7 @@ def capture_subprocess_output(subprocess_args, new_env=None, profileMode=False):
|
||||
global rocprof_args
|
||||
# Format command for debug messages, formatting for rocprofv1 and rocprofv2
|
||||
command = " ".join(rocprof_args)
|
||||
console_debug("subprocess", "Running: " + command)
|
||||
console_debug("subprocess", "Running: " + command + " " + " ".join(subprocess_args))
|
||||
# Start subprocess
|
||||
# bufsize = 1 means output is line buffered
|
||||
# universal_newlines = True is required for line buffering
|
||||
@@ -820,7 +820,7 @@ def gen_sysinfo(
|
||||
df["workload_name"] = workload_name
|
||||
|
||||
blocks = []
|
||||
if ip_blocks == None:
|
||||
if not ip_blocks:
|
||||
t = ["SQ", "LDS", "SQC", "TA", "TD", "TCP", "TCC", "SPI", "CPC", "CPF"]
|
||||
blocks += t
|
||||
else:
|
||||
@@ -1249,3 +1249,16 @@ def merge_counters_spatial_multiplex(df_multi_index):
|
||||
|
||||
final_df = pd.concat(result_dfs, keys=coll_levels, axis=1, copy=False)
|
||||
return final_df
|
||||
|
||||
|
||||
def convert_metric_id_to_panel_idx(metric_id):
|
||||
# "4.02" -> 402
|
||||
# "4.23" -> 423
|
||||
# "4" -> 400
|
||||
tokens = metric_id.split(".")
|
||||
if len(tokens) == 1:
|
||||
return int(tokens[0]) * 100
|
||||
elif len(tokens) == 2:
|
||||
return int(tokens[0]) * 100 + int(tokens[1])
|
||||
else:
|
||||
raise Exception(f"Invalid metric id: {metric_id}")
|
||||
|
||||
Reference in New Issue