ROCm SMI Python CLI: Fix Lower Power Cap Warning
The purpose of this patch is to fix a power cap bug for --setpoweroverdrive.
This bug occurs when the user attempts to set a lower wattage than the current
or default wattage, which displays an unnecessary warning message.
Signed-off-by: Ori Messinger <Ori.Messinger@amd.com>
Change-Id: I730d2c6031b7d7c4af5acf32ecd28da5ca21ab12
[ROCm/rocm_smi_lib commit: 20e2d260fb]
This commit is contained in:
@@ -1088,9 +1088,9 @@ def setPowerOverDrive(deviceList, value, autoRespond):
|
|||||||
printLogSpacer(' Reset GPU Power OverDrive ')
|
printLogSpacer(' Reset GPU Power OverDrive ')
|
||||||
else:
|
else:
|
||||||
printLogSpacer(' Set GPU Power OverDrive ')
|
printLogSpacer(' Set GPU Power OverDrive ')
|
||||||
confirmOutOfSpecWarning(autoRespond)
|
|
||||||
# Value in Watts - stored early this way to avoid strenuous value type conversions
|
# Value in Watts - stored early this way to avoid strenuous value type conversions
|
||||||
strValue = value
|
strValue = value
|
||||||
|
specWarningConfirmed = False
|
||||||
for device in deviceList:
|
for device in deviceList:
|
||||||
power_cap_min = c_uint64()
|
power_cap_min = c_uint64()
|
||||||
power_cap_max = c_uint64()
|
power_cap_max = c_uint64()
|
||||||
@@ -1111,10 +1111,20 @@ def setPowerOverDrive(deviceList, value, autoRespond):
|
|||||||
logging.error('GPU[%s]\t\t: Value cannot be less than: %dW ', device, power_cap_min.value / 1000000)
|
logging.error('GPU[%s]\t\t: Value cannot be less than: %dW ', device, power_cap_min.value / 1000000)
|
||||||
RETCODE = 1
|
RETCODE = 1
|
||||||
return
|
return
|
||||||
new_cap = c_uint64()
|
current_power_cap = c_uint64()
|
||||||
|
default_power_cap = c_uint64()
|
||||||
|
new_power_cap = c_uint64()
|
||||||
# Wattage input value converted to microWatt for ROCm SMI Lib
|
# Wattage input value converted to microWatt for ROCm SMI Lib
|
||||||
new_cap.value = int(value) * 1000000
|
new_power_cap.value = int(value) * 1000000
|
||||||
ret = rocmsmi.rsmi_dev_power_cap_set(device, 0, new_cap)
|
ret = rocmsmi.rsmi_dev_power_cap_get(device, 0, byref(current_power_cap))
|
||||||
|
ret = rocmsmi.rsmi_dev_power_cap_set(device, 0, 0)
|
||||||
|
ret = rocmsmi.rsmi_dev_power_cap_get(device, 0, byref(default_power_cap))
|
||||||
|
if current_power_cap.value < default_power_cap.value:
|
||||||
|
current_power_cap.value = default_power_cap.value
|
||||||
|
if not specWarningConfirmed and new_power_cap.value > current_power_cap.value:
|
||||||
|
confirmOutOfSpecWarning(autoRespond)
|
||||||
|
specWarningConfirmed = True
|
||||||
|
ret = rocmsmi.rsmi_dev_power_cap_set(device, 0, new_power_cap)
|
||||||
if rsmi_ret_ok(ret, device):
|
if rsmi_ret_ok(ret, device):
|
||||||
if value == 0:
|
if value == 0:
|
||||||
power_cap = c_uint64()
|
power_cap = c_uint64()
|
||||||
@@ -1124,7 +1134,12 @@ def setPowerOverDrive(deviceList, value, autoRespond):
|
|||||||
printLog(device, 'Successfully reset Power OverDrive to: %sW' % (int(power_cap.value / 1000000)), None)
|
printLog(device, 'Successfully reset Power OverDrive to: %sW' % (int(power_cap.value / 1000000)), None)
|
||||||
else:
|
else:
|
||||||
if not PRINT_JSON:
|
if not PRINT_JSON:
|
||||||
printLog(device, 'Successfully set power to: %sW' % (strValue), None)
|
ret = rocmsmi.rsmi_dev_power_cap_get(device, 0, byref(current_power_cap))
|
||||||
|
if current_power_cap.value == new_power_cap.value:
|
||||||
|
printLog(device, 'Successfully set power to: %sW' % (strValue), None)
|
||||||
|
else:
|
||||||
|
printErrLog(device, 'Unable set power to: %sW, current value is %sW' % \
|
||||||
|
(strValue, int(current_power_cap.value / 1000000)))
|
||||||
else:
|
else:
|
||||||
if value == 0:
|
if value == 0:
|
||||||
printErrLog(device, 'Unable to reset Power OverDrive to default')
|
printErrLog(device, 'Unable to reset Power OverDrive to default')
|
||||||
|
|||||||