Correct inf loop defect in fast clock init.
Each time delay is grown we need to reset elapsed. We want to take the most accurate sample from the set at fixed delay. Without this we will hang if there is ever an insufficiently accurate, high unit clock read. Change-Id: Ic65f364067789ac85a6572d67af2d77528e265bb
此提交包含在:
@@ -57,9 +57,11 @@ fast_clock::init::init() {
|
||||
|
||||
// calibrate clock
|
||||
fast_clock::raw_rep min = 0;
|
||||
clock::duration elapsed = clock::duration::max();
|
||||
clock::duration elapsed;
|
||||
|
||||
do {
|
||||
elapsed = clock::duration::max();
|
||||
|
||||
for (int t = 0; t < 10; t++) {
|
||||
fast_clock::raw_rep r1, r2;
|
||||
clock::time_point t0, t1, t2, t3;
|
||||
|
||||
新增問題並參考