rocm_smi.py: Handle corrupted serial number
If the FRU has been corrupted, then the serial number will come in with
any manner of random bytes, which will cause decode() to fail
spectacularily. Check that the serial returned by the kernel is
alphanumeric, and print to the error log if not (then continue to the
next device).
Change-Id: If4f35b140b6089e02729b1490ed6b48d614a122a
[ROCm/amdsmi commit: 6b6e840337]
Этот коммит содержится в:
@@ -2161,6 +2161,10 @@ def showSerialNumber(deviceList):
|
||||
for device in deviceList:
|
||||
sn = create_string_buffer(256)
|
||||
ret = rocmsmi.rsmi_dev_serial_number_get(device, sn, 256)
|
||||
if not str(sn).isalnum():
|
||||
printErrLog(device, "FRU Serial Number contains non-alphanumeric characters. FRU is likely corrupted")
|
||||
continue
|
||||
|
||||
if rsmi_ret_ok(ret, device) and sn.value.decode():
|
||||
printLog(device, 'Serial Number', sn.value.decode())
|
||||
else:
|
||||
|
||||
Ссылка в новой задаче