Correct inf loop defect in fast clock init.
Each time delay is grown we need to reset elapsed. We want to take
the most accurate sample from the set at fixed delay.
Without this we will hang if there is ever an insufficiently accurate,
high unit clock read.
Change-Id: Ic65f364067789ac85a6572d67af2d77528e265bb
[ROCm/ROCR-Runtime commit: 4e9849034d]
이 커밋은 다음에 포함됨:
1 부모
cf3f441625
커밋
16efad0cdc
1 파일이 변경됨
+3
-1
@@ -57,9 +57,11 @@ fast_clock::init::init() {
|
||||
|
||||
// calibrate clock
|
||||
fast_clock::raw_rep min = 0;
|
||||
clock::duration elapsed = clock::duration::max();
|
||||
clock::duration elapsed;
|
||||
|
||||
do {
|
||||
elapsed = clock::duration::max();
|
||||
|
||||
for (int t = 0; t < 10; t++) {
|
||||
fast_clock::raw_rep r1, r2;
|
||||
clock::time_point t0, t1, t2, t3;
|
||||
|
||||
새 이슈에서 참조