Correct inf loop defect in fast clock init.
Each time delay is grown we need to reset elapsed. We want to take
the most accurate sample from the set at fixed delay.
Without this we will hang if there is ever an insufficiently accurate,
high unit clock read.
Change-Id: Ic65f364067789ac85a6572d67af2d77528e265bb
[ROCm/ROCR-Runtime commit: 4e9849034d]
Este commit está contenido en:
1 padre
cf3f441625
commit
16efad0cdc
1 file changed
+3
-1
@@ -57,9 +57,11 @@ fast_clock::init::init() {
|
||||
|
||||
// calibrate clock
|
||||
fast_clock::raw_rep min = 0;
|
||||
clock::duration elapsed = clock::duration::max();
|
||||
clock::duration elapsed;
|
||||
|
||||
do {
|
||||
elapsed = clock::duration::max();
|
||||
|
||||
for (int t = 0; t < 10; t++) {
|
||||
fast_clock::raw_rep r1, r2;
|
||||
clock::time_point t0, t1, t2, t3;
|
||||
|
||||